{"product_id":"150v-10a-150w-lcd-digital-adjustable-constant-current-electronic-load-battery-tester-lithium-dischar","title":"150V 10A 150W LCD Digital Adjustable Constant Current Electronic Load Battery Tester Lithium Dischar","description":"\u003cstrong\u003eFeatures:\u003c\/strong\u003e         ?         1. Screen and interface         2.2 inch LCM Screen, STN (yellow-green mode), display more content, large font, clear and not hurting eyes,         10 regular interfaces + 4 over-limit alarm interfaces         1 English display + 1 Chinese display (included in 10 regular display)?         2. Test input interface         Rich input interface to meet different input requirements         20A high current occlusion screw column, Type A USB, Mini USB, Micro USB, Type-C, 5.5*2.1mm male Connector         Note that only high current occlusal screw posts support up to 10A input, other ports do not support?         3. 3.7-inch fan Integrated heat sink, ABS base, with self-locking screw, firm and durable         Silent fan 22\u0026amp;pm;3dBA, bearing fan, continuous operation for more than 40,000 hours         Intelligent temperature control, automatic start and stop, automatic start at temperature over 40 ?￣C         12*12mm light touch button Comfortable and light 100,000 lifespan, one button, multiple controls,         270?￣\u0026amp;pm;5?￣ large angle adjustable knob resistance, double knob combination, easy to adjust and sensitive, quickly response         M3 copper and copper columns, the module is solid and firm         Double-layer design, simple and elegant appearance         4. Overrun protection         Voltage, current, power over-limit automatic stop input, sound + interface double alarm prompt, protection module and tested power supply, to avoid damage         Low voltage protection, over voltage protection, current over limit protection, power over limit protection         Equipped with AC100V~240V to 12V power supply, Chinese and English manual, universal         EVA lining, with easy-to-carry carton, sturdy and beautiful, cushioning and rolling?         5. Application range         General test of various power supplies, adapters, data lines, etc.         ?         \u003cstrong\u003eSpecifications:\u003c\/strong\u003e         ?         Power Voltage:DC 6~12V? ?         Interface:DC 5.0V         Voltage measure range:0~150V Accuracy:0.05V         Current adjustable range:0~10A Accuracy:0.05A         Capacity range:0~999.999Ah? Accuracy:0.001Ah         Cumulative range:0~99999.9Wh Accuracy:0.01Wh         Measure range:0~2999.9W Accuracy:0.01W         Impedance range:0~999.9?? Accuracy:0.01??         Temperature range:0~99???? Accuracy:1??????         Max timing :999:59:59? Accuracy:1s         Fan cooling power:                  \u0026lt;            150W         Fan control threshold                                                               :                                                    Temp                  \u0026gt;            40????         Standby reminder threshold                                                               :                                                                      \u0026lt;            2W\/0.5h;         Timing function                                                               :                                                                      \u0026gt;            0.5W start timing         Input interface: 20A high current occlusion screw column, type A USB,Mini USB, Micro USB, Type-C USB         Refresh time:                  \u0026gt;            500ms\/time??         Measurement rate: 0.5time\/s         Over limit alarm: interface warning and buzzer alarm         Voltage overrun auto- stops discharge range:0~150V         Current overrun auto- stops discharge range:0~10A         Power overrun auto- stops discharge range:0~150W         Display screen: LCM display         Size                                                               :                                                    149??96??80mm\/195??105??135mm         ?         Consumption                                                               :                                                                      \u0026lt;            1.5A? ??         Operating temp                                                               :                                                    -10~60????         Operating? humidity                                                               :                                                    10~80         ?         \u003cstrong\u003eMode Button Function Description:\u003c\/strong\u003e         ?         1. Click to switch each display interface         2. The function of the button operation in the 2-4 interface is as follows:         A.long press all records to clear;         B.Double-click capacity (Ah) to reset to zero;         C.three-stroke power (Wh) reset to zero;         D.four-stroke power (00:00:00) reset to zero;         E.consecutive seven hits at no load, making the current zero accurate in the current temperature environment.Calibration is zeroed for accurate measurement at low currents;Factory reset all parameters.         3. The operation functions of the buttons under the interfaces 6, 7, 9, 11, and 13 are as follows:         A.Double-click the parameter value to increase, double-click and long press the parameter to continue to increase;         B.The value of the three-stroke parameter is reduced, and the length of the three-stroke is continued to decrease.         ?         \u003cstrong\u003eHow to Use:\u003c\/strong\u003e         ?         1. Input voltage ?? current ????? 150W;         2. Turn on the load power supply, and the coarse and fine adjustment knobs will be reset to zero (counterclockwise to the end)         3. Long press the mode button to clear all data;         4. Connect to the power supply under test, and use the fine adjustment knob to slowly adjust the discharge current.When the fine adjustment cannot meet the current value, the fine adjustment is reset to zero, and the coarse adjustment knob is slowly adjusted.And with fine adjustment until the required current value is reached.         5. It is recommended to set the cutoff voltage (lower voltage input) when the battery is discharged.In order to avoid damage caused by excessive discharge.         ?         \u003cstrong\u003ePackage Included:\u003c\/strong\u003e","brand":"ZHIQIAN","offers":[{"title":"Default Title","offer_id":43928393318595,"sku":"ZHIQIAN-004779","price":979.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4355\/1683\/files\/838b0b7c-5fb2-4aaa-982c-bb50a96b93ac.jpg?v=1725736215","url":"https:\/\/wrsss.com\/products\/150v-10a-150w-lcd-digital-adjustable-constant-current-electronic-load-battery-tester-lithium-dischar","provider":"Wrsss","version":"1.0","type":"link"}