{"product_id":"xys3606w-dc-dc-buck-boost-converter-cc-cv-0-36v-6a-216w-synchronous-rectification-efficiency-95-pow","title":"XYS3606W DC DC Buck Boost Converter CC CV 0-36V 6A 216W Synchronous Rectification Efficiency 95% Pow","description":"\u003ch2\u003e\u003cb\u003eXYS3606W?Custom CNC Shell:\u003c\/b\u003e\u003c\/h2\u003e\u003cp style=\"font-size:\"\u003e\u003c\/p\u003e  \u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e  \u003ch2\u003eXYS3580?DC DC Buck Boost Converter:\u003c\/h2\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cb style=\"font-size:\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cb style=\"font-size:\"\u003eAPP download address?\u0026amp;strns;??\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003ePlease download from Google Market, search for ?????sinilink????? to download\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cb\u003eComputer client software download address?\u0026amp;strns;??\u003c\/b\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eInput voltage: 6.0-30V\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eOutput voltage: 0.0-36V\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eOutput current: 6A\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eOutput power: 216W\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eStorage space: 10 groups\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e   \u003c\/p\u003e  \u003cp class=\"p\" style=\"margin-top:\"\u003e\u003cb\u003eDetailed interface and key functions?\u0026amp;strns;??\u003c\/b\u003e   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eShort press the ?????ON\/OFF????? button to turn on and off the power output, long press the ?????ON\/OFF????? button for 2 seconds, the screen rotates and can be rotated 360?￣ in four directions.   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eRotary encoder potentiometer to realize fast page turning?????\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eShort press the code potentiometer button to activate the parameter (voltage\/current) to be set;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eSwitch between full selection and bit selection by short pressing the code potentiometer button;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eAfter selecting all, all will be displayed in reverse blue, and the set voltage\/set current can be switched through the rotary encoder;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eAfter the bit is selected, the corresponding bit will be displayed in reverse blue, and the parameters can be set through the rotary encoder;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eAfter the setting is completed, long press the code potentiometer button for 2 seconds or no button operation for more than 6 seconds will automatically exit the setting;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eAll parameters are automatically saved after exit?????\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eShort press the code potentiometer button, select all`capacity\/energy\/time`, and the corresponding one will be displayed in reverse blue after all selections. Use the rotary encoder to switch the parameter to be cleared. After selecting, short press the code potentiometer button. Clear the corresponding parameter; after selecting, long press the code potentiometer button for 2 seconds or no key operation for more than 6 seconds will automatically exit?????\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eShort press the code potentiometer button to pause\/start curve writing\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eShort press the code potentiometer button to activate the parameter to be set?\u0026amp;strns;??   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eSwitch the parameter name and position selection by short pressing the key of the code potentiometer;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eAfter selecting the parameter name, the parameter name will be displayed in reverse blue, and the parameter to be set can be switched by rotating the encoder potentiometer;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eAfter the bit is selected, the corresponding bit will be displayed in reverse blue, and the parameters can be set through the rotary encoder;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eAfter the setting is completed, long press the code potentiometer button for 2 seconds or no button operation for more than 6 seconds will automatically exit the setting;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eAll parameters are automatically saved after exit?????   \u003c\/p\u003e  \u003cp class=\"p\" style=\"margin-top:\"\u003e\u003cb\u003eData group function description?\u0026amp;strns;??\u003c\/b\u003e   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eYou can save a total of 10 data groups M0-M9, and save to data group M0 by default. Press and hold the code potentiometer button for 2 seconds on any interface to quickly call up the M1\/M2 data group. The current data group serial number will be displayed at the interface index. ?\u0026amp;strns;??   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eIn the power supply parameter setting interface, after?\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eselecting the data group, rotate the encoder potentiometer to adjust the corresponding data group;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eAfter the parameter modification in the data group is completed, the corresponding parameters will be stored in the current data group by default?????   \u003c\/p\u003e  \u003cp class=\"p\" style=\"margin-top:\"\u003eNote?\u0026amp;strns;??The power output is turned off by default after switching the data group?\u0026amp;strns;??   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eSet voltage U-SET: 0-36.00V;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eSet current I-SET: 0-6.1A;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eInput undervoltage protection LVP default: 4.0V, can be set by yourself;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eOutput overvoltage protection OVP default: 37V, can be set by yourself;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eOutput overcurrent protection OCP default: 6.2A, can be set by yourself;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eOutput over power protection OPP default: 220W, can be set by yourself;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eMaximum operating time OHP: When the parameter setting is not 0, turn on this function, and when it runs for the set time, the power supply will automatically turn off the output;\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eMaximum capacity OAH: When the parameter is not 0, turn on this function, when the capacity reaches the set parameter, the power will automatically turn off the output;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eMaximum energy OWH: When the parameter is not 0, turn on this function. When the energy reaches the set parameter, the power will automatically turn off the output;   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e   \u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eOHP\/OAH\/OWH function, can well realize timing\/quantitative power supply?????\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003eShort press the code potentiometer button to select\/switch the parameter to be set. After selecting, the parameter will be reversed and set the parameter through the rotary encoder;   \u003c\/p\u003e","brand":"ZHIQIAN","offers":[{"title":"Default Title","offer_id":43929137152195,"sku":"ZHIQIAN-040327","price":908.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/4355\/1683\/files\/37ac5e42-faf2-4b75-9c3f-20da4efacec7.jpg?v=1725767046","url":"https:\/\/wrsss.com\/products\/xys3606w-dc-dc-buck-boost-converter-cc-cv-0-36v-6a-216w-synchronous-rectification-efficiency-95-pow","provider":"Wrsss","version":"1.0","type":"link"}